Page 12 - BREDI-H-Hinge thermal break system
P. 12

THERMAL TRANSMITANCE OF Casement Window as per EN ISO 10077-2
          SPECIMEN :
                                                                 Calcula on Type :
                                                                 Simplified calculation method
                                                                 (construc on typus: drawing beside)
                            B









                                                           1.2
              A                                        A







                            B
                                  1.2




          Data from Autocad     Project Data                     Calcula on Sheeet Data
          - Projected widths a , b..h  -'Window Dimensions , L, H  - U values of Aluminium Sections
          - Area of the glass   - Glass U value
          - Area of the Spandrel                                 Results
          - Area of Aluminium Profiles                            - Mean U value of the frame
                                                                 - Mean U value of the window


          Calculation
                             H     Total window height  [m]  1.200
                             L     Total window length  [m]  1.200
                             a       Projected Width    [m]  0.087 Pannel    glazing area (projected)  [m²]  0.911
                                     area (projected)   [m²]  0.375        thermal transmittance of glass  [W/m²K]  1.160
            Frame & Sash - window
                             U f   thermal transmittance  [W/m²K]  3.770                       [W/K]  1.057
                                     Energy Transfer   [W/K]  1.415 PSI      Visible Glass Perimeter  m  5.880
                             b       Projected Width    [m]  0.138           Linear Transmitance of the   W/m  0.110
                                                                            glass Edge - as per EN ISO
                                                                        Y Y Y Y                W      0.647
                                     area (projected)   [m²]  0.154               10077-1
              Central- Window
                                   thermal transmittance  [W/m²K]  3.790
                             U f
                                     Energy Transfer   [W/K]  0.582 results                    [W/K]  3.701
                                                                             total area of the  window  [m²]  1.440
                                                                           mean thermal transmittance of
                                                                 WINDOW                      [W/m²K] 2.570
                                                                                total window
          Summary P1 to P2                             [W/K]  1.997
          Frame Area         Af     Total Frame Area    m²   0.529
          Mean U Value of Frame                      [W/m²K]  3.776


          Technoform Middle East, www.technoform.ae, middleeast@technoform.ae

          fl
          flixo pro 7.0.626.1ixo pro 7.0.626.1


  10                              4.4.3  Thermophysical analysis(Uw-window)

                                       Email: bredi@bredi.net    Phone: +974 70123568 / 66511437       visit us at : www.bredi.net
   7   8   9   10   11   12   13   14   15   16   17